{"id":526,"date":"2022-06-03T08:28:34","date_gmt":"2022-06-03T08:28:34","guid":{"rendered":"https:\/\/peer.com.au\/peerconstruction\/?page_id=526"},"modified":"2022-07-04T02:57:56","modified_gmt":"2022-07-04T02:57:56","slug":"install-lpg-gas-caravan-procedure","status":"publish","type":"page","link":"https:\/\/peer.com.au\/peerconstruction\/install-lpg-gas-caravan-procedure\/","title":{"rendered":"Install LPG gas \u2013 caravan procedure"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; admin_label=&#8221;intro background&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; background_color=&#8221;#1E1E1E&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row column_structure=&#8221;1_2,1_2&#8243; admin_label=&#8221;Title banner&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text admin_label=&#8221;Title&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;Raleway||||||||&#8221; text_text_color=&#8221;#1E1E1E&#8221; header_font=&#8221;Raleway|600|||||||&#8221; header_text_color=&#8221;#FAA61A&#8221; header_font_size=&#8221;45px&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h1>Install LPG gas \u2013 caravan procedure<\/h1>\n<p>[\/et_pb_text][\/et_pb_column][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;Raleway||||||||&#8221; text_text_color=&#8221;#FFFFFF&#8221; text_font_size=&#8221;20px&#8221; custom_padding=&#8221;||0px|||&#8221; global_colors_info=&#8221;{}&#8221;]PEER Construction is committed to the provision of a safe, healthy, and productive workplace. PEER Construction recognises that hazardous LPG Gas tasks increase the risk of injury to workers and clients and has developed policies and procedures to reduce this risk.[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row column_structure=&#8221;3_4,1_4&#8243; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;3_4&#8243; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text admin_label=&#8221;Purpose and scope&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;||0px|||&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>Purpose<\/h2>\n<p>The purpose of this procedure is to provide information on safe work procedures to:<\/p>\n<ul>\n<li>maintain a safe and healthy work environment<\/li>\n<li>address any workplace factors which may increase the risk of injuries.<\/li>\n<\/ul>\n<p>Gas installation must be carried out by a licensed plumber or a plumbing apprentice under the guidance of a licensed plumber. All employees who carry out gas installations must follow this procedure.<\/p>\n<p>[\/et_pb_text][\/et_pb_column][et_pb_column type=&#8221;1_4&#8243; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_search _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_search][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; background_color=&#8221;#F5F5F5&#8243; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text admin_label=&#8221;H2 text to accordion grey backgorund&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>Process<\/h2>\n<p>The process has the following components.<\/p>\n<p>[\/et_pb_text][et_pb_accordion admin_label=&#8221;Accordion grey background&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_accordion_item title=&#8221;Cylinder compartment specifications &#8221; open=&#8221;off&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p>Cylinder compartments and gas lockers must:<\/p>\n<ul>\n<li>be large enough to house the cylinders and their associated equipment<\/li>\n<li>allow the safe removal and reconnection of cylinders, including securing the cylinders<\/li>\n<li>have sufficient ventilation to prevent a build-up of LP gas in case of a gas leak.<\/li>\n<\/ul>\n<p>[\/et_pb_accordion_item][et_pb_accordion_item title=&#8221;Installation&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; open=&#8221;off&#8221;]<\/p>\n<p>Ensure piping is firmly fastened, protected and all unions and joints are accessible.<\/p>\n<p>Piping should be constructed from continuous lengths, from the regulator to branch points and from those points to the appliance. Piping must be continuous when passing through sleeping accommodation.<\/p>\n<p>Where piping passes through partitions or bulkheads the penetration shall be vapour-proof. Piping must be:<\/p>\n<ul>\n<li>secured against vibration<\/li>\n<li>protected where it passes through partitions or bulkheads<\/li>\n<li>sufficiently flexible to avoid excessive stresses resulting from movement of the caravan<\/li>\n<li>at least 25mm from any electrical service<\/li>\n<li>protected against abrasion, kinking, or permanent deformation.<\/li>\n<\/ul>\n<p>Where rigid piping is installed, it should be protected from direct contact with metallic parts of the structure and be at least 100mm from exposed live parts of electrical fittings.<\/p>\n<p>Do not use jointing compounds to compensate for ill-fitting joints and do not apply to compression joints, union joints or POL fittings.<\/p>\n<p>[\/et_pb_accordion_item][et_pb_accordion_item title=&#8221;Pipe supports and fixings&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; open=&#8221;off&#8221;]<\/p>\n<p>Support piping with prefabricated clips of either the same material as, or of a material compatible with, the pipe and fasten with nuts and bolts, rivets or screws.<\/p>\n<p>Supports must be provided within 150mm of every bend, elbow, tee or branch fitting, excluding loops, and elsewhere at spacings not greater than specified in AS\/NZS 5601.2: 2013.<\/p>\n<p>[\/et_pb_accordion_item][et_pb_accordion_item title=&#8221;Hose assemblies&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; open=&#8221;off&#8221;]Hose assemblies should be continuous and as short as practicable.<\/p>\n<p>They should only be used between the regulator and rigid piping or between rigid piping and the appliance. Where there is only one appliance involved, a flexible hose can be used between the regulator and the appliance.<\/p>\n<p>Protect hose assemblies from exposure to ultraviolet light. They should be separated by at least 100 mm from any part of an engine exhaust system and not subjected to temperatures above 65\u00b0C.[\/et_pb_accordion_item][et_pb_accordion_item title=&#8221;Shut-off valves&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; open=&#8221;off&#8221;]<\/p>\n<p>Each appliance must have a readily accessible (that is. without the use of a tool) shut-off valve installed (prior to the inlet connection). Valves must be of a quarter turn type and clearly indicate whether the valve is open or closed. The valve should be labelled with its purpose.<\/p>\n<p>[\/et_pb_accordion_item][et_pb_accordion_item title=&#8221;Cylinder connections&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; open=&#8221;off&#8221;]<\/p>\n<p>The high pressure piping between the cylinder and the regulator shall allow for vibration, either by including a suitable hose assembly between 500mm and 600mm long (with a nominal size of 6mm), or alternatively by providing loops or U-bends in the connecting piping.<\/p>\n<p>Always use cylinder regulators with overpressure protection so downstream pressures will not exceed 14kPa.<\/p>\n<p><strong>Quick-connect devices or crimp fit<\/strong><\/p>\n<p>Do not install quick-connect devices or crimp fit fittings (for example vega or b-press) in a caravan.<\/p>\n<p>[\/et_pb_accordion_item][et_pb_accordion_item title=&#8221;Appliances&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; open=&#8221;off&#8221;]<\/p>\n<p>Install all gas appliances in accordance with the manufacturer\u2019s instructions.<\/p>\n<p>When installing the appliance locate it such that:<\/p>\n<ul>\n<li>it may be easily ignited<\/li>\n<li>maintenance and adjustments can be performed<\/li>\n<li>there is no hazard to the caravan or its contents<\/li>\n<li>undue restriction to the movement of persons is avoided<\/li>\n<li>the risk of harm to persons is minimised<\/li>\n<li>risks associated with the storage, use or release of hazardous or flammable substances is minimised.<\/li>\n<\/ul>\n<p>Gas cookers should be installed in accordance with the manufacturer\u2019s instructions. Refer to AS\/NZS 5601.2: 2013 when installation instructions or clearances around gas cooking appliances are not specified. Always install appliances in an accessible location, with sufficient clearances to allow access to, and removal of, all serviceable components.<\/p>\n<p>Allow sufficient clearance from combustible materials so these surfaces do not exceed 65\u00b0C above ambient temperature during operation.<\/p>\n<p>Gas cooking appliances must have a warning label attached advising users that the appliance should be ventilated when in use and not used for space heating.<\/p>\n<p>If the gas cooking appliance is installed on a gimbal ensure:<\/p>\n<ul>\n<li>the gas connection is a flexible hose<\/li>\n<li>limit-stops are fitted to allow movement but minimise hose stresses<\/li>\n<li>clearances to combustible surfaces are maintained, otherwise you must fit a heat deflector<\/li>\n<li>the appliance remains within the gimbal at all angles of tilt<\/li>\n<li>movement is prevented when the appliance is not in use.<\/li>\n<\/ul>\n<p>[\/et_pb_accordion_item][et_pb_accordion_item title=&#8221;Ventilation &#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; open=&#8221;off&#8221;]<\/p>\n<ul>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"14\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559684&quot;:-2,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" aria-setsize=\"-1\" data-aria-posinset=\"2\" data-aria-level=\"1\">All gas appliances should be approved for use and installed by a licensed gas fitter.\u00a0<\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"14\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559684&quot;:-2,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" aria-setsize=\"-1\" data-aria-posinset=\"3\" data-aria-level=\"1\">Gas appliances should be serviced according to the manufacturer\u2019s instructions or at least every 2 years by a licensed gas fitter.\u00a0<\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"14\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559684&quot;:-2,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" aria-setsize=\"-1\" data-aria-posinset=\"3\" data-aria-level=\"1\">Gas appliances installed inside caravans require permanent ventilation. Ensure ventilation openings are not blocked or restricted.\u00a0<\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"14\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559684&quot;:-2,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" aria-setsize=\"-1\" data-aria-posinset=\"3\" data-aria-level=\"1\">Gas appliances approved for outdoor use are not permitted to be installed or used inside the caravan.<\/li>\n<\/ul>\n<p>[\/et_pb_accordion_item][et_pb_accordion_item title=&#8221;Gas tightness&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; open=&#8221;off&#8221;]A gas tightness test should be carried out on all new installations and modifications to existing installations. Ensure any pressure drop or leakage rate does not exceed a limit specified by the technical regulator.[\/et_pb_accordion_item][et_pb_accordion_item title=&#8221;Commissioning of appliance&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; open=&#8221;off&#8221;]<\/p>\n<p>When commissioning a gas appliance consider the appliance\u2019s features and safety requirements and the manufacturer\u2019s instructions.<\/p>\n<p>Check that LP gas locker or cylinder compartment labels are displayed in prominent positions and cylinders and cylinder restraints are in good order.<\/p>\n<p>Set the regulator outlet pressure to 3.0 kPa with all gas appliances operating simultaneously.<\/p>\n<p>Check the appliance is in safe working order by:<\/p>\n<ul>\n<li>testing and purging the appliance and the installation<\/li>\n<li>igniting each burner and adjusting where necessary<\/li>\n<li>testing the flue\u2019s performance<\/li>\n<li>testing all safety devices.<\/li>\n<\/ul>\n<p>[\/et_pb_accordion_item][et_pb_accordion_item title=&#8221;Handover &#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; open=&#8221;on&#8221;]Instruct the client on the safe operation of the appliance and provide the client with operating instructions.[\/et_pb_accordion_item][\/et_pb_accordion][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_tabs admin_label=&#8221;References and related&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_tab title=&#8221;References&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p>Work Health and Safety Act 2012 (SA)<br \/>Work Health and Safety Regulations 2012 (SA)<br \/>Environment Protection Act 1993<\/p>\n<p>[\/et_pb_tab][et_pb_tab title=&#8221;Related&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]WHS policies and procedures[\/et_pb_tab][et_pb_tab title=&#8221;Version &#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p>Version 1.0 &#8211; Last updated 19\/2\/2022<\/p>\n<p>[\/et_pb_tab][\/et_pb_tabs][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; fullwidth=&#8221;on&#8221; _builder_version=&#8221;4.17.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Install LPG gas \u2013 caravan procedurePEER Construction is committed to the provision of a safe, healthy, and productive workplace. PEER Construction recognises that hazardous LPG Gas tasks increase the risk of injury to workers and clients and has developed policies and procedures to reduce this risk.Purpose The purpose of this procedure is to provide information [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"class_list":["post-526","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/peer.com.au\/peerconstruction\/wp-json\/wp\/v2\/pages\/526","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/peer.com.au\/peerconstruction\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/peer.com.au\/peerconstruction\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/peer.com.au\/peerconstruction\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/peer.com.au\/peerconstruction\/wp-json\/wp\/v2\/comments?post=526"}],"version-history":[{"count":5,"href":"https:\/\/peer.com.au\/peerconstruction\/wp-json\/wp\/v2\/pages\/526\/revisions"}],"predecessor-version":[{"id":1412,"href":"https:\/\/peer.com.au\/peerconstruction\/wp-json\/wp\/v2\/pages\/526\/revisions\/1412"}],"wp:attachment":[{"href":"https:\/\/peer.com.au\/peerconstruction\/wp-json\/wp\/v2\/media?parent=526"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}